Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Hand Surg Asian Pac Vol ; 29(1): 36-42, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38299239

RESUMO

Background: Despite the good clinical results in the treatment of Kienböck disease with distal radius core decompression, a radiological progression to a certain degree in the long-term follow-up is possible. Is there a negative correlation between the clinical improvement of the patients and the radiological progression? Methods: We retrospectively reviewed the radiological and clinical results of 24 patients (mean age: 38 years; 10 women) treated with core decompression for Kienböck disease. The mean follow-up was 10 years. Results: A radiologic progression in the Lichtman classification was seen in nine patients. The Spearman correlation did not show any correlation between this radiological progression and the clinical outcome. Namely -0.06 between Mayo and Lichtman classification and 0.16 between VAS and Lichtman classification. Conclusions: We found that the clinical outcomes do not deteriorate despite a radiological progression of patients treated with core decompression for Kienböck disease Level of Evidence: Level IV (Therapeutic).


Assuntos
Osteonecrose , Rádio (Anatomia) , Humanos , Feminino , Adulto , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Estudos Retrospectivos , Seguimentos , Osteotomia/métodos , Osteonecrose/diagnóstico por imagem , Osteonecrose/cirurgia , Descompressão
2.
Medicina (Kaunas) ; 58(6)2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35744007

RESUMO

Background and Objectives: Three-dimensional planning and guided osteotomy utilizing patient-specific instrumentation (PSI) with the contralateral side used as a reference have been proven as effective in the treatment of malunions following complex fractures of the distal radius. However, this approach has not yet been described in relation to fracture reduction of the distal radius. The aim of this study was to assess the technical and logistical feasibility of computer-assisted surgery in a clinical setting using PSI for fracture reduction and fixation. Materials and Methods: Five patients with varied fracture patterns of the distal radius underwent operative treatment with using PSI. The first applied PSI guide allowed specific and accurate placement of Kirschner wires inside the multiple fragments, with subsequent concurrent reduction using a second guide. Results: Planning, printing of the guides, and operations were performed within 5.6 days on average (range of 1-10 days). All patients could be treated within a reasonable period of time, demonstrating good outcomes, and were able to return to work after a follow-up of three months. Mean wrist movements (°) were 58 (standard deviation (SD) 21) in flexion, 62 (SD 15) in extension, 73 (SD 4) in pronation and 74 (SD 10) in supination at a minimum follow-up of 6 months. Conclusions: Three-dimensional planned osteosynthesis using PSI for treatment of distal radius fractures is feasible and facilitates reduction of multiple fracture fragments. However, higher costs must be taken into consideration for this treatment.


Assuntos
Fraturas do Rádio , Fios Ortopédicos , Fixação de Fratura , Fixação Interna de Fraturas , Humanos , Osteotomia/métodos , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
3.
J Hand Surg Am ; 47(7): 691.e1-691.e10, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34507869

RESUMO

PURPOSE: Our study aimed to analyze the functional and radiological intermediate-term outcome of 3-dimensional-guided corrective osteotomies for malunited distal radius fractures and to evaluate the progression of osteoarthritis after this intervention. METHODS: All patients with malunited distal radius fractures who underwent 3-dimensional-guided corrective osteotomies from October 2008 to January 2015 were included. Pre- and postoperative range of motion, grip strength, and postoperative patient-reported outcomes were assessed. Pre- and postoperative osteoarthritis grading was performed using conventional radiographs and the osteoarthritis grading system described by Knirk and Jupiter. Additionally, the evaluation of articular stepoff was performed using pre- and postoperative computed tomography. RESULTS: Fifteen patients, with a mean follow-up of 6 years (range, 4.1-10.4 years), were included. According to rater 1, 8 cases had no postoperative osteoarthritis progression, 6 cases had progression of 1 grade, and 1 case had progression of 2 grades. According to rater 2, there was no progression in 11 cases, and there was progression of 1 grade in 2 cases and progression of 2 grades in 2 cases. Compared with before the surgery, the patients demonstrated a mean improvement of 14.8 kg (±12.6 kg) in grip strength after the surgery. At the last follow-up, the mean Patient-Rated Wrist Evaluation score was 11.8 (±12.0), the mean Disabilities of the Arm, Shoulder and Hand score was 11.1 (±11.4), and the mean residual pain score on the visual analog scale was 0.8 (±1.0). CONCLUSIONS: The intermediate-term outcome of 3-dimensional-guided corrective osteotomies for distal radius intra-articular malunions showed excellent patient-reported outcomes and no clinically relevant progression of osteoarthritis. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Fraturas Mal-Unidas , Osteoartrite , Fraturas do Rádio , Seguimentos , Fraturas Mal-Unidas/diagnóstico por imagem , Fraturas Mal-Unidas/cirurgia , Humanos , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Osteotomia/métodos , Rádio (Anatomia) , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
4.
Eur Spine J ; 30(12): 3731-3737, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34350487

RESUMO

PURPOSE: Augmented reality (AR) is an emerging technology with great potential for surgical navigation through its ability to provide 3D holographic projection of otherwise hidden anatomical information. This pilot cadaver study investigated the feasibility and accuracy of one of the first holographic navigation techniques for lumbar pedicle screw placement. METHODS: Lumbar computer tomography scans (CT) of two cadaver specimens and their reconstructed 3D models were used for pedicle screw trajectory planning. Planned trajectories and 3D models were subsequently uploaded to an AR head-mounted device. Randomly, k-wires were placed either into the left or the right pedicle of a vertebra (L1-5) with or without AR-navigation (by holographic projection of the planned trajectory). CT-scans were subsequently performed to assess accuracy of both techniques. RESULTS: A total of 18 k-wires could be placed (8 navigated, 10 free hand) by two experienced spine surgeons. In two vertebrae, the AR-navigation was aborted because the registration of the preoperative plan with the intraoperative anatomy was imprecise due to a technical failure. The average differences of the screw entry points between planning and execution were 4.74 ± 2.37 mm in the freehand technique and 5.99 ± 3.60 mm in the AR-navigated technique (p = 0.39). The average deviation from the planned trajectories was 11.21° ± 7.64° in the freehand technique and 5.88° ± 3.69° in the AR-navigated technique (p = 0.09). CONCLUSION: This pilot study demonstrates improved angular precision in one of the first AR-navigated pedicle screw placement studies worldwide. Technical shortcomings need to be eliminated before potential clinical applications.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Cirurgia Assistida por Computador , Cadáver , Humanos , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Projetos Piloto
5.
J Orthop Surg Res ; 16(1): 159, 2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33632251

RESUMO

BACKGROUND: Computer-assisted three-dimensional (3D) planning is increasingly delegated to biomedical engineers. So far, the described fracture reduction approaches rely strongly on the performance of the users. The goal of our study was to analyze the influence of the two different professional backgrounds (technical and medical) and skill levels regarding the reliability of the proposed planning method. Finally, a new fragment displacement measurement method was introduced due to the lack of consistent methods in the literature. METHODS: 3D bone models of 20 distal radius fractures were presented to nine raters with different educational backgrounds (medical and technical) and various levels of experience in 3D operation planning (0 to 10 years) and clinical experience (1.5 to 24 years). Each rater was asked to perform the fracture reduction on 3D planning software. RESULTS: No difference was demonstrated in reduction accuracy regarding rotational (p = 1.000) and translational (p = 0.263) misalignment of the fragments between biomedical engineers and senior orthopedic residents. However, a significantly more accurate planning was performed in these two groups compared with junior orthopedic residents with less clinical experience and no 3D planning experience (p < 0.05). CONCLUSION: Experience in 3D operation planning and clinical experience are relevant factors to plan an intra-articular fragment reduction of the distal radius. However, no difference was observed regarding the educational background (medical vs. technical) between biomedical engineers and senior orthopedic residents. Therefore, our results support the further development of computer-assisted surgery planning by biomedical engineers. Additionally, the introduced fragment displacement measure proves to be a feasible and reliable method. LEVEL OF EVIDENCE: Diagnostic Level II.


Assuntos
Competência Clínica , Escolaridade , Fixação de Fratura/métodos , Imageamento Tridimensional/métodos , Planejamento de Assistência ao Paciente , Fraturas do Rádio/cirurgia , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Internato e Residência , Masculino , Pessoa de Meia-Idade , Cirurgiões Ortopédicos , Cuidados Pré-Operatórios , Estudos Retrospectivos , Adulto Jovem
6.
Arch Orthop Trauma Surg ; 141(9): 1447-1453, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32715400

RESUMO

BACKGROUND: Accurate glenoid positioning in reverse total shoulder arthroplasty (RSA) is important to achieve satisfying functional outcome and prosthesis longevity. Optimal component placement can be challenging, especially in severe glenoid deformities. The use of patient-specific instruments (PSI) and 3D computer-assisted optical tracking navigation (NAV) are already established methods to improve surgical precision. Augmented reality technology (AR) promises similar results at low cost and ease of use. With AR, the planned component placement can be superimposed to the surgical situs and shown directly in the operating field using a head mounted display. We introduce a new navigation technique using AR via head mounted display for surgical navigation in this feasibility study, aiming to improve and enhance the surgical planning. METHODS: 3D surface models of ten human scapulae were printed from computed tomography (CT) data of cadaver scapulae. Guidewire positioning of the central back of the glenoid baseplate was planned with a dedicated computer software. A hologram of the planned guidewire with dynamic navigation was then projected onto the 3D-created models of the cadaver shoulders. The registration of the plan to the anatomy was realized by digitizing the glenoid surface and the base of the coracoid with optical tracking using a fiducial marker. After navigated placement of the central guidewires, another CT imaging was recorded, and the 3D model was superimposed with the preoperative planning to analyze the deviation from the planned and executed central guides trajectory and entry point. RESULTS: The mean deviation of the ten placed guidewires from the planned trajectory was 2.7° ± 1.3° (95% CI 1.9°; 3.6°). The mean deviation to the planned entry point of the ten placed guidewires measured 2.3 mm ± 1.1 mm (95% CI 1.5 mm; 3.1 mm). CONCLUSION: AR may be a promising new technology for highly precise surgical execution of 3D preoperative planning in RSA.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Articulação do Ombro , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Articulação do Ombro/cirurgia
7.
J Orthop Surg Res ; 15(1): 540, 2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33203429

RESUMO

BACKGROUND: The Ganz' periacetabular osteotomy (PAO) consists of four technically challenging osteotomies (OT), namely, supraacetabular (saOT), pubic (pOT), ischial (iOT), and retroacetabular OT (raOT). PURPOSE: We performed a proof of concept study to test (1) the feasibility of augmented reality (AR) guidance for PAO, (2) precision of the OTs guided by AR compared to the freehand technique performed by an experienced PAO surgeon, and (3) the effect of AR on performance depending on experience. METHODS: A 3D preoperative plan of a PAO was created from segmented computed tomography (CT) data of an anatomic plastic pelvis model (PPM). The plan was then embedded in a software application for an AR head-mounted device. Soft tissue coverage was imitated using foam rubber. The 3D plan was then registered onto the PPM using an anatomical landmark registration. Two surgeons (one experienced and one novice PAO surgeon) each performed 15 freehand (FH) and 15 AR-guided PAOs. The starting point distances and angulation between the planned and executed OT planes for the FH and the AR-guided PAOs were compared in post-intervention CTs. RESULTS: AR guidance did not affect the performance of the expert surgeon in terms of the mean differences between the planned and executed starting points, but the raOT angle was more accurate as compared to FH PAO (p = 0.0027). AR guidance increased the accuracy of the performance of the novice surgeon for iOT (p = 0.03). An intraarticular osteotomy performed by the novice surgeon with the FH technique could be observed only once. CONCLUSION: AR guidance of osteotomies for PAOs is feasible and seems to increase accuracy. The effect is more accentuated for less-experienced surgeons. CLINICAL RELEVANCE: This is the first proof of concept study documenting the feasibility of AR guidance for PAO. Based on these findings, further studies are essential for elaborating on the potential merits of AR guidance to increase the accuracy of complex surgical procedures.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Realidade Aumentada , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Osteotomia/métodos , Cirurgia Assistida por Computador/métodos , Estudos de Viabilidade , Luxação do Quadril/cirurgia , Humanos , Modelos Anatômicos
8.
J Hand Surg Am ; 45(10): 918-923, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32711962

RESUMO

PURPOSE: To investigate the residual articular incongruity on computed tomography image data and the early clinical outcome of 3-dimensional planned and navigated intra-articular osteotomies of the distal radius. METHODS: We conducted a retrospective analysis of intra-articular osteotomies executed between 2008 and 2016. We identified 37 patients (aged 26-73 years) and performed a combined intra-articular and extra-articular osteotomy on 20 patients. A preoperative 3-dimensional plan with the superimposed bone of the contralateral healthy side was performed in each case to analyze and execute the osteotomy by intraoperative navigation. The residual articular incongruity was assessed by quantification of the maximal stepoff in the coronal or sagittal computed tomography scans. Clinical outcome, including range of motion, grip strength, and return to work, was assessed after a minimum follow-up of 12 months and compared with preoperative measurements. RESULTS: On average, the preoperative intra-articular stepoff was 2.5 mm (±0.6 mm; range, 1.4-4.2 mm) and was significantly reduced to 0.8 mm (±0.2 mm) after surgery. After surgery, 30 patients had a stepoff less than 1 mm; in 7, a stepoff of 1.1 to 1.4 mm was measured. After 1 year, 22 had no pain, 9 had slight pain during heavy work, and 5 had moderate pain with no improvement compared with their preoperative status, although wrist strength and range of motion improved in all 37 patients. One patient underwent a secondary radioscapholunate arthrodeses owing to persistent pain despite a congruent joint with a small residual intra-articular stepoff (0.6 mm). CONCLUSIONS: Intra-articular osteotomies of the distal radius treated by 3-dimensional preoperative planning and patient-specific guides are an accurate technique to reduce articular incongruity to an average stepoff of 0.8 mm (range, 0.3-1.4 mm). The early clinical outcomes demonstrated overall reduction in pain and improvement of range of motion and grip strength in 36 of 37 patients. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Fraturas Mal-Unidas , Fraturas do Rádio , Fraturas Mal-Unidas/diagnóstico por imagem , Fraturas Mal-Unidas/cirurgia , Humanos , Rádio (Anatomia) , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
9.
J Hand Surg Am ; 45(11): 1083.e1-1083.e11, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32553556

RESUMO

PURPOSE: To develop reproducible 3-dimensional measurements for quantification of the distal radioulnar joint (DRUJ) morphology. We hypothesized that automated 3-dimensional measurement of the ulnar variance (UV) and the sigmoid notch (SN) angle would be comparable to those of the reference standard while overcoming some drawbacks of conventional 2-dimensional measurements. METHODS: Radiological data of healthy forearm bones (radiographs and computed tomography) of 53 adult subjects were included in the study. Automated measurements were developed for assessment of the SN morphology based on 3-dimensional landmarks, incorporating subject-specific estimation of cartilage surface orientation. A common anatomical reference was defined among the different imaging modalities and a comparison of the SN angle and UV measurements was performed in radiographs, computed tomography scans, and 3-dimensional models. Finally, the 3-dimensional UV measurements were evaluated in an experimental setup using 3-dimensional printed bone models. RESULTS: The automated 3-dimensional measurements of SN subtypes showed a notably larger notch radius (18.9 mm) for negative SN angles compared with positive SN angles in subjects (16.9 mm). Similar UV measurements were obtained in healthy DRUJ morphologies, with a high correlation between radiographs and 3-dimensional measurements for the SN angle (0.77) and UV (0.85). In the experimental setup with pathological radial inclinations, UV was on average 1.13 mm larger in the radiographs compared with the 3-dimensional measurements, and 1.30 mm larger in the cases with pathological palmar tilts. Furthermore, UV radiograph measurements on the modified palmar tilt deviated from the 3-dimensional measurements. CONCLUSIONS: The developed 3-dimensional automated measurements were able to quantify morphological differences among sigmoid notch subtypes and were comparable to those of the reference standard. CLINICAL RELEVANCE: The developed methods do not depend on the forearm position or orientation of the distal radius and can be used for 3-dimensional quantification of DRUJ pathologies in 3-dimensional surgical planning.


Assuntos
Ulna , Articulação do Punho , Adulto , Antebraço , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ulna/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem
10.
Spine J ; 20(4): 621-628, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31669611

RESUMO

BACKGROUND CONTEXT: Due to recent developments in augmented reality with head-mounted devices, holograms of a surgical plan can be displayed directly in the surgeon's field of view. To the best of our knowledge, three dimensional (3D) intraoperative fluoroscopy has not been explored for the use with holographic navigation by head-mounted devices in spine surgery. PURPOSE: To evaluate the surgical accuracy of holographic pedicle screw navigation by head-mounted device using 3D intraoperative fluoroscopy. STUDY DESIGN: In this experimental cadaver study, the accuracy of surgical navigation using a head-mounted device was compared with navigation with a state-of-the-art pose-tracking system. METHODS: Three lumbar cadaver spines were embedded in nontransparent agar gel, leaving only commonly visible anatomy in sight. Intraoperative registration of preoperative planning was achieved by 3D fluoroscopy and fiducial markers attached to lumbar vertebrae. Trackable custom-made drill sleeve guides enabled real-time navigation. In total, 20 K-wires were navigated into lumbar pedicles using AR-navigation, 10 K-wires by the state-of-the-art pose-tracking system. 3D models obtained from postexperimental CT scans were used to measure surgical accuracy. MF is the founder and shareholder of Incremed AG, a Balgrist University Hospital start-up focusing on the development of innovative techniques for surgical executions. The other authors declare no conflict of interest concerning the contents of this study. No external funding was received for this study. RESULTS: No significant difference in accuracy was measured between AR-navigated drillings and the gold standard with pose-tracking system with mean translational errors between entry points (3D vector distance; p=.85) of 3.4±1.6 mm compared with 3.2±2.0 mm, and mean angular errors between trajectories (3D angle; p=.30) of 4.3°±2.3° compared with 3.5°±1.4°. CONCLUSIONS: In conclusion, holographic navigation by use of a head-mounted device achieve accuracy comparable to the gold standard of high-end pose-tracking systems. CLINICAL SIGNIFICANCE: These promising results could result in a new way of surgical navigation with minimal infrastructural requirements but now have to be confirmed in clinical studies.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Cirurgia Assistida por Computador , Fluoroscopia , Humanos , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia
11.
Med Image Anal ; 60: 101598, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31731091

RESUMO

Three-dimensional (3D) computer-assisted corrective osteotomy has become the state-of-the-art for surgical treatment of complex bone deformities. Despite available technologies, the automatic generation of clinically acceptable, ready-to-use preoperative planning solutions is currently not possible for such pathologies. Multiple contradicting and mutually dependent objectives have to be considered, as well as clinical and technical constraints, which generally require iterative manual adjustments. This leads to unnecessary surgeon efforts and unbearable clinical costs, hindering also the quality of patient treatment due to the reduced number of solutions that can be investigated in a clinically acceptable timeframe. In this paper, we propose an optimization framework for the generation of ready-to-use preoperative planning solutions in a fully automatic fashion. An automatic diagnostic assessment using patient-specific 3D models is performed for 3D malunion quantification and definition of the optimization parameters' range. Afterward, clinical objectives are translated into the optimization module, and controlled through tailored fitness functions based on a weighted and multi-staged optimization approach. The optimization is based on a genetic algorithm capable of solving multi-objective optimization problems with non-linear constraints. The framework outputs a complete preoperative planning solution including position and orientation of the osteotomy plane, transformation to achieve the bone reduction, and position and orientation of the fixation plate and screws. A qualitative validation was performed on 36 consecutive cases of radius osteotomy where solutions generated by the optimization algorithm (OA) were compared against the gold standard solutions generated by experienced surgeons (Gold Standard; GS). Solutions were blinded and presented to 6 readers (4 surgeons, 2 planning engineers), who voted OA solutions to be better in 55% of the time. The quantitative evaluation was based on different error measurements, showing average improvements with respect to the GS from 20% for the reduction alignment and up to 106% for the position of the fixation screws. Notably, our algorithm was able to generate feasible clinical solutions which were not possible to obtain with the current state-of-the-art method.


Assuntos
Algoritmos , Antebraço/diagnóstico por imagem , Antebraço/cirurgia , Imageamento Tridimensional , Osteotomia/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Pontos de Referência Anatômicos , Antebraço/anatomia & histologia , Humanos , Modelagem Computacional Específica para o Paciente
13.
Int J Comput Assist Radiol Surg ; 14(7): 1157-1165, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30993519

RESUMO

PURPOSE: In spinal fusion surgery, imprecise placement of pedicle screws can result in poor surgical outcome or may seriously harm a patient. Patient-specific instruments and optical systems have been proposed for improving precision through surgical navigation compared to freehand insertion. However, existing solutions are expensive and cannot provide in situ visualizations. Recent technological advancement enabled the production of more powerful and precise optical see-through head-mounted displays for the mass market. The purpose of this laboratory study was to evaluate whether such a device is sufficiently precise for the navigation of lumbar pedicle screw placement. METHODS: A novel navigation method, tailored to run on the Microsoft HoloLens, was developed. It comprises capturing of the intraoperatively reachable surface of vertebrae to achieve registration and tool tracking with real-time visualizations without the need of intraoperative imaging. For both surface sampling and navigation, 3D printable parts, equipped with fiducial markers, were employed. Accuracy was evaluated within a self-built setup based on two phantoms of the lumbar spine. Computed tomography (CT) scans of the phantoms were acquired to carry out preoperative planning of screw trajectories in 3D. A surgeon placed the guiding wire for the pedicle screw bilaterally on ten vertebrae guided by the navigation method. Postoperative CT scans were acquired to compare trajectory orientation (3D angle) and screw insertion points (3D distance) with respect to the planning. RESULTS: The mean errors between planned and executed screw insertion were [Formula: see text] for the screw trajectory orientation and 2.77±1.46 mm for the insertion points. The mean time required for surface digitization was 125±27 s. CONCLUSIONS: First promising results under laboratory conditions indicate that precise lumbar pedicle screw insertion can be achieved by combining HoloLens with our proposed navigation method. As a next step, cadaver experiments need to be performed to confirm the precision on real patient anatomy.


Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
14.
BMC Musculoskelet Disord ; 19(1): 403, 2018 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-30454041

RESUMO

Following publication of the original article [1], the author pointed out that the references were numbered incorrectly. This error was introduced during the production process. The original article has been corrected.

15.
BMC Musculoskelet Disord ; 19(1): 374, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30322393

RESUMO

BACKGROUND: Opening-wedge osteotomies of the distal radius, performed with three-dimensional printed patient-specific instruments, are a promising technique for accurate correction of malunions. Nevertheless, reports of residual malalignments and discrepancies in the plate and screw position from the planned fixation exist. Consequently, we developed a patient-specific ramp-guide technique, combining navigation of plate positioning, osteotomy cutting, and reduction. The aim of this study is to compare the accuracy of navigation of three-dimensional planned opening-wedge osteotomies, using a ramp-guide, over state-of-the-art guide techniques relying solely on pre-drilled holes. METHODS: A retrospective analysis was carried out on opening-wedge osteotomies of the distal radius, performed between May 2016 and April 2017, with patient-specific instruments. Eight patients were identified in which a ramp-guide for the distal plate fixation was used. We compared the reduction accuracy with a control group of seven patients, where the reduction was performed with pre-drilled screw holes placed with the patient-specific instruments. The navigation accuracy was assessed by comparing the preoperative plans with the postoperative segmented, computed tomography scans. The accuracy was expressed using a 3D angle and in measurements of all six degrees of freedom (3 translations, 3 rotations), with respect to an anatomical coordinate system. RESULTS: The duration of the surgery of the ramp-guide group was significantly shorter compared to the control group. Significantly less rotational and translational residual malalignment error was observed in the open-wedged osteotomies, where patient-specific instruments with ramp-guides were used. On average, a residual rotational malalignment error of 2.0° (± 2.2°) and a translational malalignment error of 0.6 mm (± 0.2 mm) was observed in the ramp-guide group, as compared to the 4.2° (± 15.0°) and 1.0 mm (± 0.4 mm) error in the control group. The used plate was not significantly positioned more accurately, but significantly fewer screws (15.6%) were misaligned in the distal fragment compared to the control group (51.9%). CONCLUSION: The use of the presented ramp-guide technique in opening-wedge osteotomies is improving reduction accuracy, screw position, and surgical duration, compared to the existing patient-specific instrument based navigation methods.


Assuntos
Fixação de Fratura/métodos , Fraturas Mal-Unidas/cirurgia , Osteotomia/instrumentação , Fraturas do Rádio/cirurgia , Cirurgia Assistida por Computador/instrumentação , Adolescente , Adulto , Idoso , Placas Ósseas , Parafusos Ósseos , Estudos de Casos e Controles , Criança , Fixação de Fratura/instrumentação , Fraturas Mal-Unidas/diagnóstico por imagem , Fraturas Mal-Unidas/etiologia , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Duração da Cirurgia , Osteotomia/métodos , Planejamento de Assistência ao Paciente , Impressão Tridimensional , Fraturas do Rádio/complicações , Fraturas do Rádio/diagnóstico por imagem , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
16.
Orthop J Sports Med ; 6(2): 2325967117752907, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29450206

RESUMO

BACKGROUND: Passive glenohumeral range of motion may be characteristically limited to specific shoulder pathologies. While pain associated with loss of range of passive external glenohumeral rotation is recognized as a salient feature in adhesive capsulitis, restriction of glenohumeral range of motion in calcific tendinitis of the supraspinatus tendon has never been studied. HYPOTHESIS: On the basis of clinical observation, we hypothesized that calcific tendinitis of the supraspinatus tendon is associated with loss of passive glenohumeral abduction without loss of external rotation. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Ranges of passive glenohumeral rotation and abduction, which are measured with a standardized protocol in our institution, were retrospectively reviewed and compared for patients diagnosed with either adhesive capsulitis or calcific tendinitis of the supraspinatus tendon. A total of 57 patients met the inclusion criteria for the calcific tendinitis, and 77 met the inclusion criteria for the adhesive capsulitis group. RESULTS: When compared with the contralateral, unaffected shoulder, glenohumeral abduction in the calcific tendinitis group was restricted by a median of 10° (interquartile range [IQR], -20° to -5°) as opposed to glenohumeral external rotation, which was not restricted at all (median, 0°; IQR, 0° to 0°). The adhesive capsulitis group showed a median restriction of glenohumeral abduction of 40° (IQR, -50° to -30°) and a median restriction of passive glenohumeral external rotation of 40° (IQR, -60° to -30°). CONCLUSION: Calcific tendinitis of the supraspinatus does not typically cause loss of external rotation but is frequently associated with mild isolated restriction of abduction. This finding can be used to clinically differentiate adhesive capsulitis from calcific tendinitis.

17.
J Hand Surg Am ; 42(12): 1031.e1-1031.e8, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28888571

RESUMO

PURPOSE: To investigate the reduction accuracy of 3-dimensional planned single-cut osteotomies (SCOTs) of the forearm that were performed using patient-specific guides. METHODS: A retrospective analysis of SCOTs performed between 2012 and 2014 was performed. Ten patients (age, 15-59 years) with 6 malunions of the ulna and 6 malunions of the radius were identified. The reduction accuracy was assessed by comparing the 3-dimensional preoperative plan of each osteotomy with the superimposed bone model extracted from postoperative computed tomography data. The difference was assessed by 3-dimensional angle and in all 6 degrees of freedom (3 translations, 3 rotations) with respect to an anatomical coordinate system. Wrist range of motion and grip strength was assessed after a mean of 16.7 months and compared with the preoperative measurements. RESULTS: On average, the 12 SCOTs demonstrated excellent accuracy of the reduction with respect to rotation (ie, pronation/supination, 4.9°; flexion/extension, 1.7°; ulnar/radial angulation, 2.0°) and translation (ie, proximal/distal, 0.8 mm; radial/ulnar, 0.8 mm; dorsal/palmar, 0.8 mm). A mean residual 3-dimensional angle of 5.8° (SD, 3.6°) was measured after surgery. All 6 patients operated on for reasons of a reduced range of motion demonstrated improved symptoms and increased movement (from 20° to 80°). In the patients with unstable/painful distal radioulnar joint, 3 were totally free of complaints and 1 patient showed residual pain during sports. CONCLUSIONS: A SCOT combined with patient-specific guides is an accurate and reliable technique to restore normal anatomy in multiplanar deformities of the forearm. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Fixação de Fratura , Fraturas Mal-Unidas/cirurgia , Imageamento Tridimensional , Osteotomia , Fraturas do Rádio/cirurgia , Fraturas da Ulna/cirurgia , Adolescente , Adulto , Feminino , Fraturas Mal-Unidas/diagnóstico por imagem , Força da Mão , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas do Rádio/diagnóstico por imagem , Amplitude de Movimento Articular , Estudos Retrospectivos , Cirurgia Assistida por Computador , Resultado do Tratamento , Fraturas da Ulna/diagnóstico por imagem , Articulação do Punho , Adulto Jovem
18.
BMC Musculoskelet Disord ; 12: 175, 2011 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-21798008

RESUMO

BACKGROUND: Beside symptoms and clinical signs radiological findings are crucial in the diagnosis of lumbar spinal stenosis (LSS). We investigate which quantitative radiological signs are described in the literature and which radiological criteria are used to establish inclusion criteria in clinical studies evaluating different treatments in patients with lumbar spinal stenosis. METHODS: A literature search was performed in Medline, Embase and the Cochrane library to identify papers reporting on radiological criteria to describe LSS and systematic reviews investigating the effects of different treatment modalities. RESULTS: 25 studies reporting on radiological signs of LSS and four systematic reviews related to the evaluation of different treatments were found. Ten different parameters were identified to quantify lumbar spinal stenosis. Most often reported measures for central stenosis were antero-posterior diameter (< 10 mm) and cross-sectional area (< 70 mm(2)) of spinal canal. For lateral stenosis height and depth of the lateral recess, and for foraminal stenosis the foraminal diameter were typically used. Only four of 63 primary studies included in the systematic reviews reported on quantitative measures for defining inclusion criteria of patients in prognostic studies. CONCLUSIONS: There is a need for consensus on well-defined, unambiguous radiological criteria to define lumbar spinal stenosis in order to improve diagnostic accuracy and to formulate reliable inclusion criteria for clinical studies.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética , Estenose Espinal/diagnóstico , Tomografia Computadorizada por Raios X , Humanos , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...